40A Schneider Electric Type B Pack – Electrical Protection for 22kW Three-Phase Charging Station

SKU 069 - 066.2 Category ELECTRICAL MODULES
logo

Schneider Electric Type B pack – Type B electrical protection dedicated to 22kW three-phase charging stations.

Share
This pack contains:

- 1 Schneider residual current device Type B - 3P+N - 63A - 30mA

- 1 Schneider Acti9 iC magneto-thermal circuit breaker - 3P+N - 40A - Curve C

Type B Electrical Protection Pack for 22 kW three-phase charging station.

The following electrical protections must be connected on a dedicated circuit.

Protections required for a three-phase connection:
- Residual current device 63A - Type B - 3P+N - 30mA
- Circuit breaker 40A Curve C - 3P+N - breaking capacity 10kA

1/ Type B - 63A - three-phase residual current device
The residual current device Type B - 63A - 3P+N - 30mA is essential for any charging station installation.

It continuously monitors the incoming and outgoing current, and opens the circuit as soon as the difference exceeds 30mA. This function ensures protection against the risk of electric shock.

Compatibility with all three-phase stations
This residual current device is suitable for all three-phase charging stations available on the market with a charging current between 1 and 32A, including those not fitted with a DC leakage current detector.

If your station is already equipped with a DC leakage current detector, a less expensive Type A three-phase residual current device will be sufficient.

It must always be paired with a circuit breaker.

Installation
It must be connected on a circuit exclusively dedicated to the charging station, downstream of the main residual current device in the electrical panel.

The station must have its own dedicated circuit, with its own circuit breaker and its own residual current device.

Main specifications
- Type: B
- Poles: 3P+N
- Rated current: 63A max
- Rated residual current: 30mA

2/ Schneider 40A three-phase circuit breaker
The Schneider Acti9 iC magneto-thermal circuit breaker - 3P+N - 40A - Curve C is essential for any charging station installation. It protects the installation against overvoltages and short circuits.

Its Curve C is particularly suited to high-current equipment such as charging stations. Its high breaking capacity and fast disconnection guarantee safety, reliability and long service life.

Compatibility
This circuit breaker is designed for a station set between 6A and 32A.

It must always be paired with the residual current device.

Installation
It must be mounted in the electrical panel, on the dedicated residual current device circuit for the charging station. The station must have its own dedicated circuit, with its own circuit breaker and its own residual current device.

Main specifications
- Number of poles: 3P+N
- Supply voltage: 400V
- Breaking current: 40A
- Breaking capacity: 6-10kA
- Curve: C

Dedicated Circuit and Mandatory Electrical Protection

A Wallbox EV charging station must be installed on a dedicated circuit, with its own circuit breaker and its own residual current device (RCD). The main specifications to be taken into account when selecting the electrical protection devices are set out below:

Single-phase installation:

  • Residual Current Device (RCD): Type B, 30mA, 2P or 1P+N. A Type A or Type F RCD may be used instead of a Type B RCD when the charging station is equipped with an appropriate 6mA DC residual current detection device, ensuring disconnection of the power supply in the event of a continuous DC residual fault current exceeding 6mA.
  • Circuit breaker: Minimum Type C tripping characteristic, with a breaking capacity suitable for the installation, 2P or 1P+N. Its rated current must be determined according to the rated current or the maximum configured charging current of the charging station, as well as the characteristics of the circuit.

Three-phase installation:

  • Residual Current Device (RCD): Type B, 30mA, 4P. A Type A or Type F RCD may be used instead of a Type B RCD when the charging station is equipped with an appropriate 6mA DC residual current detection device, ensuring disconnection of the power supply in the event of a continuous DC residual fault current exceeding 6mA.
  • Circuit breaker: Minimum Type C tripping characteristic, with a breaking capacity suitable for the installation, 4P or 3P+N. Its rated current must be determined according to the rated current or the maximum configured charging current of the charging station, as well as the characteristics of the circuit.

Connection Cable Cross-Sections

The cable sizes below are provided as minimum reference cross-sections for the configurations indicated. They provide an initial guideline for connecting an EV charging station:

  • 16A Wallbox charging station or 16A socket outlet: minimum reference cross-section 2.5mm²
  • 32A Wallbox charging station: minimum reference cross-section 10mm²
  • 63A Wallbox charging station: minimum reference cross-section 16mm², subject to verification according to the installation characteristics

The final sizing of the circuit must, however, be determined according to the actual characteristics of the installation. The required conductor cross-section depends in particular on the current, circuit length, installation method, ambient temperature, number of loaded conductors, applicable correction factors and permissible voltage drop.

A conductor cross-section greater than the values indicated above may therefore be required, particularly for long cable runs or specific installation conditions.

Connection Cable Cross-Sections – NF C 15-100 and NF C 15-100-7-722

Charging Station or Socket Outlet

Rated current: 16A
Circuit breaker rating: 20A
Minimum reference cross-section: 2.5mm²

Charging Station

Rated current: 32A
Circuit breaker rating: 40A
Minimum reference cross-section: 10mm²

Charging Station

Rated current: 63A
Circuit breaker rating: To be sized according to the installation
Minimum reference cross-section: 16mm² minimum*

* For a charging station operating at 63A, a 16mm² conductor cross-section is provided as an indicative minimum value and must not automatically be associated with an 80A circuit breaker. The rating of the protective device and the conductor cross-section must be determined together according to the actual characteristics of the installation. A larger conductor cross-section may be required.

Important

The values provided above are general sizing guidelines and do not replace a detailed assessment of the electrical installation.

In accordance with the requirements of NF C 15-100 and NF C 15-100-7-722, the power supply to an EV charging station must be provided by a dedicated circuit. The sizing of the cables and protective devices must be determined according to the rated current of the charging station or its maximum configured charging current, as well as the specific characteristics of the installation.

The installer must verify, in particular, the cable run length, installation method, voltage drop, thermal conditions, permissible current-carrying capacity of the conductors and required breaking capacity before determining the final conductor cross-section and ratings of the electrical protective devices.

The installation and connection of an EV charging station must comply with all applicable regulations and standards.
This information is provided for guidance only and is not a substitute for advice from a qualified professional electrician.